User’s Guide
Shop online at
omega.com
e-mail: [email protected]
For latest product manuals:
omegamanual.info
TM
WITH BUILT-IN
PATENTED
LASER CIRCLE
SIGHTING
OSXL650
and OSXL653
Low Cost Professional
Infrared Thermometer
1-3 Warnings and Cautions
2
3
3
3
4
6
6
6
7
4-4 Advanced Functions
7
10
10
11
11
7.Emissivity Table
12
Low Cost Professional Infrared Thermometer
i
NOTES:
Low Cost Professional Infrared Thermometer
larger than the unit’s optical field of view.
(OSXL653).
Patented laser circle sighting.
Temperature data storge (OSXL653).
Audible alarms (OSXL653).
LoDwowCnolosatdPfrroomfeWsswiwon.SaolmIannfuraalrse.cdomTh. AelrlmMoanmuaeltseSrearch And Download.
1-3 Warnings and Cautions
CAUTION
You may receive harmful laser radiation exposure if you
do not adhere to the warnings listed below:
• Use of controls or adjustments or performance of
procedures other than those specified here may
result in hazardous radiation exposure.
• Do not look at the laser beam coming out of the
lens or view directly with optical instruments - eye
damage can result.
• Use extreme caution when operating the laser
sighting.
• Never point the laser beam at a person.
• Do not attempt to open the thermometer. There are
no user serviceable parts.
• Keep out of the reach of all children.
Refer to the inside back cover for product warning label.
Download from WwwL.SoowmaCnousatlsP.croomf.eAslsl iMoannaulaIlsnSfreaarrechdATnhdeDrmowonmloaedte. r
LoDwowCnolosatdPfrroomfeWsswiown.SaolmIannfuraalrse.cdomTh. AelrlmMoanmuaeltseSrearch And Download.
-32 to 538°C (-25 to 1000°F)
From -32 to -20°C (-25 to -4°F)
From -20 to 100°C (-4 to 212°F)
100 to 538°C (-212 to 1000°F)
to
0 to 50°C (32 to 212°F)
10 to 90%RH
Adj. 0.1 to 1.0 (OSXL653).
0.95 Fixed (OSXL650).
YES - Laser Circle
YES (OSXL653)
YES
10 points (OSXL653)
YES (OSXL653)
Max//Min/Avg/ T
Auto-measuring
Data Storage
Audible Alarm
187g Approx.
Low Cost Professional Infrared Thermometer
3.Specifications con’t.
Laser Sighting
Wavelength (Color):
Operating Distance:
630 to 670 nanometers (red)
Up to 10 ft.
Max. Output Optical
Power:
<1mW at 75°F ambient
temperature,
Class II Laser Product
European Classification: Class 2, EN60825-1
FDA Classification:
Complies with 21 CFR Chapter 1,
Subchapter J
Beam Diameter:
Beam Divergence:
Laser Configuration:
Power Switch:
5 mm
<2mrad
Dot and Circle
Slide switch, ON-OFF
Laser icon on display
Supplied by the thermometer
Power Indicator:
Power:
Identification Label:
Located on the right side of the
thermometer
Warning and
Certification Label:
Located on the left side of the
thermometer
Low Cost Professional Infrared Thermometer
LCD displays either the current temperature in degree
Celsius or Fahrenheit. The unit will HOLD the last
reading for about 6 seconds after the trigger is
released; the word HOLD appears. Make sure the
target area is larger than the field of view of this
instrument. The laser circle sighting indicates the
perimeter of the thermometer’s field of view. During
the measurement session, the display back light
stays on.
Laser Circle
Sighting
ID and Field
of View Label
Optical Lens
Download from WwwL.SoowmaCnousatlsP.croomfe. AsslliMoannaulaIlsnfSreaarrechd ATnhdeDrmowonmloeadte. r
(OSXL653)
(OSXL653)
Complies with 21 CFR, Chapter 1, subchapter J
Laser Warning and
Certification Label
Laser Aperture
the battery voltage is low
and battery symbol
appears.
LoDwowCnolosatdPfrroomfeWsswiown.SaolmIannfuraalrse.cdomTh. AelrlmMoanmuealtseSrearch And Download.
4-4 Advanced Functions (OSXL653)
4-4-1 AUTO Mode-Continuous
Operation
From the SCAN mode (Trigger is pulled), you can
lock the trigger electronically and measure
temperature continuously (AUTO mode) by pressing
the F key. The AUTO icon will appear on the display.
Pressing the F key again will disable the AUTO
mode. AUTO icon will disappear from the display. If
the trigger is pulled, the unit stays in the SCAN
mode. If the trigger is released, the unit will go to
HOLD mode and will shut itself off after about 6
seconds.
The following table shows an overall functional flow
chart of the thermometer:
Mode
SCAN
AUTO
DATA
Press F Key
SCAN AUTO
AUTO DATA
Press Up Key
Press Down Key
----
----
+ Memory
Location
----
----
- Memory
Location
DATA Max Temp
Max Temp Max Temp Min Temp
Min Temp Min Temp Avg Temp
----
----
----
----
Avg Temp
∆T
Avg Temp ∆T
Emissivity
----
----
----
----
T
Emissivity Emissivity High Alarm
+ Emissivity
– Emissivity
HAL
LAL
High Alarm Low Alarm + Alarm Set Point – Alarm Set Point
Low Alarm SCAN/HOLD + Alarm Set Point – Alarm Set Point
Download from WwwL.SoowmaCnousatlsP.croomfe. AsslliMoannaulaIlsnfSreaarrechdATnhdeDrmowonmloeadte. r
4-4-2 Max, Min, Avg, ∆T Temperatures
(OSXL653)
You can review the Maximum, Minimum, Average,
and differential (Max - Min) temperatures on the
display by pressing the F key. If the trigger is pulled
at the same time, the display will show SCAN icon
and all the values are in real time. If the trigger is
released, the display will show the HOLD icon and
all the values are the last readings before the trigger
is released.
4-4-3 Temperature Data Storage &
Recall - DATA Mode (OSXL653)
You can store up to 10 temperature data points
(Memory Location 0 thru 9). When you are in DATA
mode, set the memory location using the Up or
Down keys, then pull the trigger. The unit will store
the temperature data in the next memory location.
You can review (recall) the stored data by going to
the DATA mode using the F key (Trigger is released)
and pressing the UP/Down keys. You can then
review memory locations 0 thru 9.
NOTE
The unit stores all temperature data, Emissivity
value, high and low alarm set points in the
non-volatile memory, Changing the battery will not
affect these values.
Low Cost Professional Infrared Thermometer
distance from the target to the target diameter. When
measuring a target temperature, the target area has
to be larger than the thermometer field of view
(FOV).
Download from WwwL.SoowmaCnousatlsP.croomf.eAslsl iMoannaulalIsnSfreaarrechdATnhdeDrmowonmloaedte. r
PATENT NOTICE:
U.S. PAT. B1 5,368,392; 5,524,984; 5,727,880; 5,823,678;
5,823,679; 6,123,453; 6,267,500 B1; 6,341,891 B1;
6,377,400 B1; 6,540,398 B2; 6,614,830 B1; 6,633,434 B2;
6,659,639; 6,901,089 B1 / Canada 2,114,806; 2,317,734 /
France 2 756 920; 2 767 921; 2 773 213; 2 773 214 /
Germany G 94 22 197.9; G 94 22 203.7 / Holland
1007752; / U.K. Registered 2,237,493; 2,320,324;
9726133.3 / EPO 0 644,408 B2; EPO 1085 307 A1.
Other U.S. and Foreign Patents Pending.
Low Cost Professional Infrared Thermometer
7.Emissivity Table
Download from WwwL.SoowmaCnousatlsP.croomf.eAslsl iMoannaulalIsnSfreaarrechdATnhdeDrmowonmloaedt.er
NOTES:
Low Cost Professional Infrared Thermometer
NOTES:
Low Cost Professional Infrared Thermometer
WARRANTY/DISCLAIMER
OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials
and workmanship for a period of 13 months from date of purchase. OMEGA’s
WARRANTY adds an additional one (1) month grace period to the normal one
(1) year product warranty to cover handling and shipping time. This ensures
that OMEGA’s customers receive maximum coverage on each product.
If the unit malfunctions, it must be returned to the factory for evaluation.
OMEGA’s Customer Service Department will issue an Authorized Return (AR)
number immediately upon phone or written request. Upon examination by
OMEGA, if the unit is found to be defective, it will be repaired or replaced at no
charge. OMEGA’s WARRANTY does not apply to defects resulting from any
action of the purchaser, including but not limited to mishandling, improper
interfacing, operation outside of design limits, improper repair, or unauthorized
modification. This WARRANTY is VOID if the unit shows evidence of having
been tampered with or shows evidence of having been damaged as a result of
excessive corrosion; or current, heat, moisture or vibration; improper specifica-
tion; misapplication; misuse or other operating conditions outside of OMEGA’s
control. Components in which wear is not warranted, include but are not limited
to contact points, fuses, and triacs.
OMEGA is pleased to offer suggestions on the use of its various products.
However, OMEGA neither assumes responsibility for any omissions or errors
nor assumes liability for any damages that result from the use of its
products in accordance with information provided by OMEGA, either verbal
or written. OMEGA warrants only that the parts manufactured by the
compamy will be as specified and free of defects. OMEGA MAKES NO
OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER,
EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED
WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED.
LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are
exclusive, and the total liability of OMEGA with respect to this order,
whether based on contract, warranty, negligence, indemnification, strict
liability or otherwise, shall not exceed the purchase price of the component
upon which liability is based. In no event shall OMEGA be liable for
consequential, incidental or special damages.
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it
be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), used in or with any
nuclear installation or activity; or (2) in medical applications or used on humans.
Should any Product(s) be used in or with any nuclear installation or activity,
medical application, used on humans, or misused in any way, OMEGA assumes
no responsibility as set forth in our basic WARRANTY/ DISCLAIMER language,
and, additionally, purchaser will indemnify OMEGA and hold OMEGA harmless
from any liability or damage whatsoever arising out of the use of the Product(s) in
RETURN REQUESTS / INQUIRIES
Direct all warranty and repair requests/inquiries to the OMEGA Customer
Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA,
PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM
OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID
PROCESSING DELAYS). The assigned AR number should then be marked on
the outside of the return package and on any correspondence.
The purchaser is responsible for shipping charges, freight, insurance and proper
packaging to prevent breakage in transit.
FOR WARRANTY RETURNS, please
FOR NON-WARRANTY REPAIRS,
have the following information
consult OMEGA for current repair
available BEFORE contacting OMEGA: charges. Have the following information
available BEFORE contacting OMEGA:
1. Purchase Order number to cover the
COST of the repair,
2. Model and serial number of the
product, and
3. Repair instructions and/or specific
problems relative to the product.
1. Purchase Order number under
which the product was
PURCHASED,
2. Model and serial number of the
product under warranty, and
3. Repair instructions and/or specific
problems relative to the product.
OMEGA’s policy is to make running changes, not model changes, whenever an
improvement is possible. This affords our customers the latest in technology
and engineering.
OMEGA is a registered trademark of OMEGA ENGINEERING, INC.
© Copyright 2006 OMEGA ENGINEERING, INC. All rights reserved. This docu-
ment may not be copied, photocopied, reproduced, translated, or reduced to any
electronic medium or machine-readable form, in whole or in part, without the
prior written consent of OMEGA ENGINEERING, INC.
Where Do I Find Everything I Need for
Process Measurement and Control?
OMEGA…Of Course!
Shop online at omega.com
TEMPERATURE
Ⅺ
ߜ Thermocouple, RTD & Thermistor Probes,
Connectors, Panels & Assemblies
Wire: Thermocouple, RTD & Thermistor
Calibrators & Ice Point References
Recorders, Controllers & Process Monitors
Infrared Pyrometers
Ⅺ
ߜ Ⅺ
ߜ Ⅺ
ߜ Ⅺ
ߜ PRESSURE, STRAIN AND FORCE
Ⅺ
ߜ Ⅺ
ߜ Ⅺ
ߜ Ⅺ
ߜ Transducers & Strain Gages
Load Cells & Pressure Gages
Displacement Transducers
Instrumentation & Accessories
FLOW/LEVEL
Ⅺ
ߜ Ⅺ
ߜ Ⅺ
ߜ Ⅺ
ߜ Rotameters, Gas Mass Flowmeters & Flow Computers
Air Velocity Indicators
Turbine/Paddlewheel Systems
Totalizers & Batch Controllers
pH/CONDUCTIVITY
Ⅺ
ߜ Ⅺ
ߜ Ⅺ
ߜ Ⅺ
ߜ pH Electrodes, Testers & Accessories
Benchtop/Laboratory Meters
Controllers, Calibrators, Simulators & Pumps
Industrial pH & Conductivity Equipment
DATA ACQUISITION
Ⅺ
ߜ Ⅺ
ߜ Ⅺ
ߜ Ⅺ
ߜ Ⅺ
ߜ Data Acquisition & Engineering Software
Communications-Based Acquisition Systems
Plug-in Cards for Apple, IBM & Compatibles
Datalogging Systems
Recorders, Printers & Plotters
HEATERS
Ⅺ
ߜ Ⅺ
ߜ Ⅺ
ߜ Ⅺ
ߜ Ⅺ
ߜ Heating Cable
Cartridge & Strip Heaters
Immersion & Band Heaters
Flexible Heaters
Laboratory Heaters
ENVIRONMENTAL
MONITORING AND CONTROL
Ⅺ
ߜ Ⅺ
ߜ Ⅺ
ߜ Ⅺ
ߜ Ⅺ
ߜ Ⅺ
ߜ Metering & Control Instrumentation
Refractometers
Pumps & Tubing
Air, Soil & Water Monitors
Industrial Water & Wastewater Treatment
pH, Conductivity & Dissolved Oxygen Instruments
M4297/0706
|